Image hover effect image

BRAVOOSMO

THE INTELLIGENT CHOICE FOR YOUR GOAL.

Image hover effect image

bravoosmo

THE INTELLIGENT CHOICE FOR YOUR GOAL.

Reverse osmosis water demineralizers

The BRAVOOSMO reverse osmosis demineralizer systems are supplied assembled on a solid AISI 304 stainless steel skid and constructed in a compact manner. Thanks to a careful design study, BRAVOOSMO demineralizer systems are optimized to increase system productivity and minimize the concentrated water to be discharged.

The systems are equipped with a microprocessor control unit for the automatic management of the process, minimizing the interventions of technical personnel during the operation phases of the system.

The BRAVOOSMO devices produce top quality demineralised water (with low salt content, intended for human consumption, food and other applications) automatically and guaranteed over time;

Water Treatment Industry|BRAVOOSMO reverse osmosis demineralizer

TECHNICAL SPECIFICATIONS

Demineralized water flow rate 80 l/h
Waste water flow rate lt/h 30 ÷ 55
Feed water flow rate l/h 110 ÷ 135
Recovery % 75 ÷ 60
Membrane quantity 1
Installed pump power kW 0.5
Inlet water operating pressure min/max bar 1 - 5
Inlet water operating temperature min/max °C 5 - 40
Ambient temperature °C 5 - 40
Salt reduction of LE series membranes % 99.0
pH 5.5 - 8.5
Maximum inlet water hardness °f 100
Electrical supply 230 V - 50 Hz
Electrical protection degree (referring to the control panel) IP55

Technical datasheet

currently being updated

 

Demineralized water flow rate 160 l/h
Waste water flow rate l/h 55 ÷ 110
Feed water flow rate l/h 215 ÷ 270
Recovery % 75 ÷ 60
Membrane quantity 2
Installed pump power kW 0.5
Inlet water operating pressure min/max bar 1 - 5
Inlet water operating temperature min/max °C 5 - 40
Ambient temperature °C 5 - 40
Salt reduction of LE series membranes % 99.0
pH 5.5 - 8.5
Maximum inlet water hardness °f 100
Electrical supply 230 V - 50 Hz
Electrical protection degree (referring to the control panel) IP55

Technical datasheet

currently being updated

 

Demineralized water flow rate 240 l/h
Waste water flow rate l/h 80 ÷ 160
Feed water flow rate l/h 320 ÷ 400
Recovery % 75 ÷ 60
Membrane quantity 3
Installed pump power kW 0.5
Inlet water operating pressure min/max bar 1 - 5
Inlet water operating temperature min/max °C 5 - 40
Ambient temperature °C 5 - 40
Salt reduction of LE series membranes % 99.0
pH 5.5 - 8.5
Maximum inlet water hardness °f 100
Electrical supply 230 V - 50 Hz
Electrical protection degree (referring to the control panel) IP55

Technical datasheet

currently being updated

 

Demineralised water flow rate 500 lt/h
Waste water flow rate lt/h 170 ÷ 330
Feed water flow rate l/h 670 ÷ 830
Recovery % 75 ÷ 60
Membrane quantity 2
Installed pump power kW 1.1
Inlet water operating pressure min/max bar 1 - 5
Inlet water operating temperature min/max °C 5 - 40
Ambient temperature °C 5 - 40
Salt reduction of LE PLUS series membranes % 95 - 99
pH 5.5 - 8.5
Maximum inlet water hardness °f 100
Electrical supply 230 V - 50 Hz
Electrical protection degree (referring to the control panel) IP55

Technical datasheet

currently being updated

 

Demineralized water flow rate 700 l/h
Waste water flow rate lt/h 240 ÷ 470
Feed water flow rate l/h 940 ÷ 1170
Recovery % 75 ÷ 60
Membrane quantity 3
Installed pump power kW 1.1
Inlet water operating pressure min/max bar 1 - 5
Inlet water operating temperature min/max °C 5 - 40
Ambient temperature °C 5 - 40
Salt reduction of LE PLUS series membranes % 95 - 99
pH 5.5 - 8.5
Maximum inlet water hardness °f 100
Electrical supply 230 V - 50 Hz
Electrical protection degree (referring to the control panel) IP55

Technical datasheet

currently being updated

 

Demineralised water flow rate 950 l/h
Waste water flow rate lt/h 320 ÷ 630
Feed water flow rate l/h 1270 ÷ 1580
Recovery % 75 ÷ 60
Membrane quantity 3
Installed pump power kW 1.5
Inlet water operating pressure min/max bar 1 - 5
Inlet water operating temperature min/max °C 5 - 40
Ambient temperature °C 5 - 40
Salt reduction of LE PLUS series membranes % 95 - 99
pH 5.5 - 8.5
Maximum inlet water hardness °f 100
Electrical supply 230 V - 50 Hz
Electrical protection degree (referring to the control panel) IP55

Technical datasheet

currently being updated

 

Demineralized water flow rate 1150 l/h
Waste water flow rate lt/h 400 ÷ 750
Feed water flow rate l/h 1550 ÷ 1900
Recovery % 75 ÷ 60
Membrane quantity 5
Installed pump power kW 1.5
Inlet water operating pressure min/max bar 1 - 5
Inlet water operating temperature min/max °C 5 - 40
Ambient temperature °C 5 - 40
Salt reduction of LE PLUS series membranes % 95 - 99
pH 5.5 - 8.5
Maximum inlet water hardness °f 100
Electrical supply 230 V - 50 Hz
Electrical protection degree (referring to the control panel) IP55

Technical datasheet

currently being updated

 

Demineralised water flow rate 1450 l/h
Waste water flow rate lt/h 500 ÷ 950
Feed water flow rate l/h 1950 ÷ 2400
Recovery % 75 ÷ 60
Membrane quantity 6
Installed pump power kW 1.1
Inlet water operating pressure min/max bar 1 - 5
Inlet water operating temperature min/max °C 5 - 40
Ambient temperature °C 5 - 40
Salt reduction of LE PLUS series membranes % 95 - 99
pH 5.5 - 8.5
Maximum inlet water hardness °f 100
Electrical supply 230 V - 50 Hz
Electrical protection degree (referring to the control panel) IP55